Micron Document
<!DOCTYPE html>
<html class="client-nojs vector-feature-night-mode-disabled vector-feature-language-in-header-enabled vector-feature-language-in-main-page-header-disabled vector-feature-page-tools-pinned-disabled vector-feature-toc-pinned-clientpref-1 vector-feature-main-menu-pinned-disabled vector-feature-limited-width-clientpref-1 vector-feature-limited-width-content-enabled vector-feature-custom-font-size-clientpref-1 vector-feature-appearance-pinned-clientpref-1 vector-sticky-header-enabled" lang="en" dir="ltr"><head>
<meta charset="UTF-8">
<title>Inline process refractometer</title>
<meta name="viewport" content="width=device-width, initial-scale=1.0">
<link rel="canonical" href="https://en.wikipedia.org/wiki/Inline_process_refractometer"> <link href="./mw/ext.cite.styles.css" rel="stylesheet" type="text/css">
<link href="./mw/skins.vector.icons.css" rel="stylesheet" type="text/css">
<link href="./mw/skins.vector.search.codex.styles.css" rel="stylesheet" type="text/css">
<link href="./mw/skins.vector.styles.css" rel="stylesheet" type="text/css">
<link href="./mw/user.styles.css" rel="stylesheet" type="text/css">
<meta name="ResourceLoaderDynamicStyles" content="">
<link rel="stylesheet" type="text/css" href="./mw/site.styles.css">
<link rel="stylesheet" type="text/css" href="./mw/noscript.css">
<link rel="stylesheet" type="text/css" href="./footer.css">
<link rel="stylesheet" type="text/css" href="./vector-2022.css">
</head>
<body class="skin--responsive skin-vector skin-vector-search-vue mediawiki ltr sitedir-ltr mw-hide-empty-elt ns-0 ns-subject page-Inline_process_refractometer rootpage-Inline_process_refractometer skin-vector-2022 action-view">
<div class="mw-page-container">
<div class="mw-page-container-inner">
<div class="mw-content-container">
<main id="content" class="mw-body">
<header class="mw-body-header vector-page-titlebar">
<h1 id="firstHeading" class="firstHeading mw-first-heading">
<span id="openzim-page-title" class="mw-page-title-main"><span class="mw-page-title-main">Inline process refractometer</span></span>
</h1>
</header>
<a id="top"></a>
<div id="bodyContent" class="vector-body ve-init-mw-desktopArticleTarget-targetContainer" aria-labelledby="firstHeading" data-mw-ve-target-container="">
<div id="mw-content-text" class="mw-body-content mw-content-ltr" lang="en" dir="ltr"><div class="mw-content-ltr mw-parser-output" lang="en" dir="ltr">
<style data-mw-deduplicate="TemplateStyles:r1305433154">
/* start https://en.wikipedia.org/ */


.mw-parser-output .ambox{border:1px solid #a2a9b1;border-left:10px solid #36c;background-color:#fbfbfb;box-sizing:border-box}.mw-parser-output .ambox+link+.ambox,.mw-parser-output .ambox+link+style+.ambox,.mw-parser-output .ambox+link+link+.ambox,.mw-parser-output .ambox+.mw-empty-elt+link+.ambox,.mw-parser-output .ambox+.mw-empty-elt+link+style+.ambox,.mw-parser-output .ambox+.mw-empty-elt+link+link+.ambox{margin-top:-1px}html body.mediawiki .mw-parser-output .ambox.mbox-small-left{margin:4px 1em 4px 0;overflow:hidden;width:238px;border-collapse:collapse;font-size:88%;line-height:1.25em}.mw-parser-output .ambox-speedy{border-left:10px solid #b32424;background-color:#fee7e6}.mw-parser-output .ambox-delete{border-left:10px solid #b32424}.mw-parser-output .ambox-content{border-left:10px solid #f28500}.mw-parser-output .ambox-style{border-left:10px solid #fc3}.mw-parser-output .ambox-move{border-left:10px solid #9932cc}.mw-parser-output .ambox-protection{border-left:10px solid #a2a9b1}.mw-parser-output .ambox .mbox-text{border:none;padding:0.25em 0.5em;width:100%}.mw-parser-output .ambox .mbox-image{border:none;padding:2px 0 2px 0.5em;text-align:center}.mw-parser-output .ambox .mbox-imageright{border:none;padding:2px 0.5em 2px 0;text-align:center}.mw-parser-output .ambox .mbox-empty-cell{border:none;padding:0;width:1px}.mw-parser-output .ambox .mbox-image-div{width:52px}@media(min-width:720px){.mw-parser-output .ambox{margin:0 10%}}@media print{body.ns-0 .mw-parser-output .ambox{display:none!important}}


/* end https://en.wikipedia.org/ */
</style>
<p><b>Inline process refractometers</b> are a type of <a href="Refractometer" title="Refractometer">refractometer</a> designed for the continuous measurement of a <a href="Fluid" title="Fluid">fluid</a> flowing through a pipe or inside a tank. First patented by <a href="Carl_A._Vossberg_Jr." title="Carl A. Vossberg Jr.">Carl A. Vossberg Jr.</a> <a rel="nofollow" class="external text" href="https://patents.google.com/patent/US2807976A/en">US2807976A</a> - Refractometer US2549402A, these refractometers typically consist of a <a href="Sensor" title="Sensor">sensor</a>, placed inline with the fluid flow, coupled to a control box. The control box usually provides a <a href="Digital_data" title="Digital data">digital</a> readout as well as <a href="4-20_mA" class="mw-redirect" title="4-20 mA">4-20 mA</a> analog outputs and relay outputs for controlling <a href="Pumps" class="mw-redirect" title="Pumps">pumps</a> and <a href="Valves" class="mw-redirect" title="Valves">valves</a>. Instead of placing the sensor inline of the process, it can be placed in a bypass, attached by a thin tube.
</p><p>This <a href="Measurement" title="Measurement">measurement</a> has been an important element in the <a href="Process_control" class="mw-redirect" title="Process control">process control</a> of the chemical and refining, pulp and paper, food, sugar and pharmaceutical industries for more than a century. For instance, the in-line concentration measurement can be used as a real-time predictive tool for the final <a href="Concentration" title="Concentration">concentration</a>. A quick and accurate response is needed to optimize production. Cost reduction is possible by reducing the variation of mean average of the product concentration. The cost saving is related to the value of the component being measured.
</p><p>A digital inline process refractometer sensor measures the <a href="Refractive_index" title="Refractive index">refractive index</a> and the <a href="Temperature" title="Temperature">temperature</a> of the processing medium. The measurement is based on the refraction of light in the process medium, i.e. the critical angle of refraction using a light source. The measured refractive index and temperature of the process medium are sent to the control box. It calculates the concentration of the process liquid based on the <a href="Refractive_index" title="Refractive index">refractive index</a> and temperature, taking pre-defined process conditions into account. The output is typically a 4 to 20mA DC output or, increasingly, an <a href="Ethernet" title="Ethernet">Ethernet</a> signal proportional to process solution concentration, liquid density, Brix or other scale that has been selected for the instrument.<sup id="cite_ref-1" class="reference"><a href="#cite_note-1"><span class="cite-bracket">[</span>1<span class="cite-bracket">]</span></a></sup>
</p><p>The inline process refractometer consists of three primary components: the inline sensing head, the electronics console, and the process adapter. The inline sensing head is mounted on the adapter and contains a prism that scans the process solution through a transparent window and outputs a value relative to the refractive index of the solution. The electronics console houses all control circuitry, microprocessors, digital displays and calibration points and conditions the sensing head signal. The process adapter is the mechanical connection between the inline sensing head and the process piping, and is designed specifically to accommodate the pipe size and application.
</p><p>Inline process refractometers are used primarily in the pulp and paper industry;<sup id="cite_ref-2" class="reference"><a href="#cite_note-2"><span class="cite-bracket">[</span>2<span class="cite-bracket">]</span></a></sup> the food and <a href="Drink_industry" title="Drink industry">beverage industry</a>,<sup id="cite_ref-3" class="reference"><a href="#cite_note-3"><span class="cite-bracket">[</span>3<span class="cite-bracket">]</span></a></sup> the pharmaceutical industry, and the chemical industry as a means to assure consistency and quality. In the <a href="Pulp_and_paper_industry" title="Pulp and paper industry">pulp and paper industry</a>, inline process refractometers are used in the energy recovery from <a href="Black_liquor" title="Black liquor">black liquor</a> recovery boilers by accurately measuring solids in the black liquor.<sup id="cite_ref-4" class="reference"><a href="#cite_note-4"><span class="cite-bracket">[</span>4<span class="cite-bracket">]</span></a></sup> In the food and beverage industry, inline process refractometers are used to measure dissolved solids, most often as sugar content, measured in <a href="Degrees_Brix" class="mw-redirect" title="Degrees Brix">degrees Brix</a>. In the pharmaceutical industry they are used to monitor and control concentration levels during supersaturation, a critical process in crystallization.<sup id="cite_ref-5" class="reference"><a href="#cite_note-5"><span class="cite-bracket">[</span>5<span class="cite-bracket">]</span></a></sup> In the chemical industry they are used in <a href="Hydrochloric_acid" title="Hydrochloric acid">Hydrochloric Acid</a> applications, <a href="Sulfuric_acid" title="Sulfuric acid">Sulphuric Acid</a> applications, and boiler cleaning chemicals processes.
</p>
<div class="mw-heading mw-heading2"><h2 id="References">References</h2></div>
<style data-mw-deduplicate="TemplateStyles:r1239543626">
/* start https://en.wikipedia.org/ */


.mw-parser-output .reflist{margin-bottom:0.5em;list-style-type:decimal}@media screen{.mw-parser-output .reflist{font-size:90%}}.mw-parser-output .reflist .references{font-size:100%;margin-bottom:0;list-style-type:inherit}.mw-parser-output .reflist-columns-2{column-width:30em}.mw-parser-output .reflist-columns-3{column-width:25em}.mw-parser-output .reflist-columns{margin-top:0.3em}.mw-parser-output .reflist-columns ol{margin-top:0}.mw-parser-output .reflist-columns li{page-break-inside:avoid;break-inside:avoid-column}.mw-parser-output .reflist-upper-alpha{list-style-type:upper-alpha}.mw-parser-output .reflist-upper-roman{list-style-type:upper-roman}.mw-parser-output .reflist-lower-alpha{list-style-type:lower-alpha}.mw-parser-output .reflist-lower-greek{list-style-type:lower-greek}.mw-parser-output .reflist-lower-roman{list-style-type:lower-roman}


/* end https://en.wikipedia.org/ */
</style><div class="reflist">
<div class="mw-references-wrap"><ol class="references">
<li id="cite_note-1"><span class="mw-cite-backlink"><b><a href="#cite_ref-1">^</a></b></span> <span class="reference-text"><style data-mw-deduplicate="TemplateStyles:r1238218222">
/* start https://en.wikipedia.org/ */


.mw-parser-output cite.citation{font-style:inherit;word-wrap:break-word}.mw-parser-output .citation q{quotes:"\"""\"""'""'"}.mw-parser-output .citation:target{background-color:rgba(0,127,255,0.133)}.mw-parser-output .id-lock-free.id-lock-free a{background:url("./mw/Lock-green.svg")right 0.1em center/9px no-repeat}.mw-parser-output .id-lock-limited.id-lock-limited a,.mw-parser-output .id-lock-registration.id-lock-registration a{background:url("./mw/Lock-gray-alt-2.svg")right 0.1em center/9px no-repeat}.mw-parser-output .id-lock-subscription.id-lock-subscription a{background:url("./mw/Lock-red-alt-2.svg")right 0.1em center/9px no-repeat}.mw-parser-output .cs1-ws-icon a{background:url("./mw/Wikisource-logo.svg")right 0.1em center/12px no-repeat}body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-free a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-limited a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-registration a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-subscription a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .cs1-ws-icon a{background-size:contain;padding:0 1em 0 0}.mw-parser-output .cs1-code{color:inherit;background:inherit;border:none;padding:inherit}.mw-parser-output .cs1-hidden-error{display:none;color:var(--color-error,#d33)}.mw-parser-output .cs1-visible-error{color:var(--color-error,#d33)}.mw-parser-output .cs1-maint{display:none;color:#085;margin-left:0.3em}.mw-parser-output .cs1-kern-left{padding-left:0.2em}.mw-parser-output .cs1-kern-right{padding-right:0.2em}.mw-parser-output .citation .mw-selflink{font-weight:inherit}@media screen{.mw-parser-output .cs1-format{font-size:95%}html.skin-theme-clientpref-night .mw-parser-output .cs1-maint{color:#18911f}}@media screen and (prefers-color-scheme:dark){html.skin-theme-clientpref-os .mw-parser-output .cs1-maint{color:#18911f}}


/* end https://en.wikipedia.org/ */
</style><cite class="citation web cs1"><a rel="nofollow" class="external text" href="http://www.liquidsolidscontrol.com/how-refractometers-work">"Technique | Refractometer principle of operation | LSC Process monitor"</a>.</cite></span>
</li>
<li id="cite_note-2"><span class="mw-cite-backlink"><b><a href="#cite_ref-2">^</a></b></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="https://blog.electronmachine.com/2016/11/inline-refractometers-for-measuring.html">"Inline Refractometers for Measuring Black Liquor Evaporation"</a>. <i>blog.electronmachine.com</i><span class="reference-accessdate">. Retrieved <span class="nowrap">2018-08-23</span></span>.</cite></span>
</li>
<li id="cite_note-3"><span class="mw-cite-backlink"><b><a href="#cite_ref-3">^</a></b></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="https://blog.electronmachine.com/2016/08/refractometer-for-juice-concentration.html">"Refractometer for Juice Concentration Processing"</a>. <i>blog.electronmachine.com</i><span class="reference-accessdate">. Retrieved <span class="nowrap">2018-08-23</span></span>.</cite></span>
</li>
<li id="cite_note-4"><span class="mw-cite-backlink"><b><a href="#cite_ref-4">^</a></b></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="http://blrbac.org/guidelines">"Guidelines &amp; Recommended Practices | blrbac.org"</a>. <i>blrbac.org</i><span class="reference-accessdate">. Retrieved <span class="nowrap">2018-08-23</span></span>.</cite></span>
</li>
<li id="cite_note-5"><span class="mw-cite-backlink"><b><a href="#cite_ref-5">^</a></b></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="https://blog.electronmachine.com/2018/04/process-refractometers-for-food-and.html">"Process Refractometers for Food and Pharmaceutical Processing"</a>. <i>blog.electronmachine.com</i><span class="reference-accessdate">. Retrieved <span class="nowrap">2018-08-23</span></span>.</cite></span>
</li>
</ol></div></div></div><!--htdig_noindex--><div><div class="zim-footer">
This article is issued from <a class="external text" title="Last edited on 2025-08-06" href="https://en.wikipedia.org/wiki/?title=Inline_process_refractometer&amp;oldid=1304534726">Wikipedia</a>. The text is available under <a class="external text" href="https://creativecommons.org/licenses/by-sa/4.0/deed.en">Creative Commons Attribution-Share Alike 4.0</a> unless otherwise noted. Additional terms may apply for the media files.
</div>
</div><!--/htdig_noindex--></div>
</div>
</main>
</div>
</div>
</div>

</body></html>